How to adjust the maximum temperature of CW-5200 chiller

Thank you for using S&A chiller, you can set temperature of S&A chiller at 5 to 35 degree C. To extend the chiller'life, Please keep the temperature between 20℃ and 30℃.
S&A chiller has 2 temperature control modes as T503 intelligent temperature and T504 constant temperature control.
If the chiller is T503 mode, please follow below steps:
Firstly, please change intelligent temperature to constant temperature mode
1. Press and keep holding ▲and SET buttons, then wait for 5 seconds until "0" displayed
2. Press ▲ key  to switch to "8" and release the key
3. Press "SET" key, and it displays "F0"
4. Press ▲ to turn to item "F3"
5. Press "SET" key and it displays "1"
6. Press▼ to adjust to "0"
7. Press "RST" key to save the modification
Now  the chiller is working in constant temperature mode.

Under constant temperature mode, you can manually adjust the temperature of S&A water chiller
For exmaple, to set the water temperature at 35℃
1. Press and keep holding ▲and SET buttons
 
2. Then for 5 seconds and it displays "0"
 
3. Press ▲ key  to switch to "8" and release the key
 
4. Press "SET" key, and it displays "F0"
 
5. Press  "SET" key again
 
6. Press▼ to adjust to "35"
 
7. Press "RST" key to save the modification
 
 
 