Customer: How to select a water chiller for cooling a laser cutter equipped with a 120W RF laser source
S&A: CW-6100 water chiller ofr 4200W cooling capacity is suitable for that
CW-6100 chiller technical parameter
Model | CW-6100AH | CW-6100BH | CW-6100AI | CW-6100BI | CW-6100AN | CW-6100BN | |
Voltage | 220V | 220V | 220V | 220V | 220V | 220V | |
Frequency | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |
Current | 1~6.5A | 1.5~7A | 2~7.5A | ||||
Compressor power | 1.38KW | 1.29KW | 1.38KW | 1.29KW | 1.38KW | 1.29KW | |
1.84HP | 1.72HP | 1.84HP | 1.72HP | 1.84HP | 1.72HP | ||
Refrigeration capacity | 14483Btu/h | 14092Btu/h | 14483Btu/h | 14092Btu/h | 14483Btu/h | 14092Btu/h | |
4.24KW | 4.13KW | 3.38KW | 4.24KW | 4.13KW | 3.38KW | ||
3650Kcal/h | 3551Kcal/h | 3650Kcal/h | 3551Kcal/h | 3650Kcal/h | 3551Kcal/h | ||
Refrigerant | R-22/R-410a | ||||||
Refrigerant charge | 950g | 900g | 950g | 900g | 950g | 900g | |
Precision | ±0.5℃ | ||||||
Reducer | Capillary | ||||||
Protection | Overcurrent protection for compressor, flow alarm, over temperature alarm | ||||||
Pump power | 0.05KW | 0.1KW | 0.37~0.75KW | ||||
Tank capacity | 15L | ||||||
Inlet and outlet | Rp1/2" | ||||||
Max. lift | 12M | 25M | 28~53M | ||||
Max. flow | 13L/min | 16L/min | 70L/min | ||||
N.W | 65Kgs | 77Kgs | |||||
G.W | 75Kgs | 87Kgs | |||||
Dimension | 67 X 47 X 89 cm (L X W X H) | ||||||
Package dimension | 74X 60 X 109 cm (L X W X H) |